PH Ions & Conductivity Meter
Features
| Corrosion resistant HIPS plastic body |
| Easy to use, built-in, menu-driven instructions on 7" touch screen TFT display |
| Mouse and keyboard connectivity |
| USB port for printer is provided for direct printout without using PC (having Linux support) |
| Pen drive connectivity |
| GLP Compliance reports with Time, Date and sample identification number facility |
| Calibration methods can be stored |
| 1000 reports can be stored |
| Automatic Temperature Compensation |
| Data Logging and Reporting: The authenticity of the reports generated can be ensured with the date/time indication in the report. The reports can be seen on the display |
| Manual Data Logging: Large memory to store 1000 reports |
| Automatic Data Logging: To store the pH value at specified time intervals (selectable from 1 to 999 minutes) up to 50 readings can be taken |
Specifications
| Model: | EzpHCon |
| Parameters: | pH, ORP, mV, Temperature, Resistivity, Salinity, TDS, Conductivity |
| pH | |
| pH Range: | 0 to 14.000 pH |
| Display Capacity: | -2.000 to 20.000 pH |
| pH Resolution: | 0.001 pH |
| pH Accuracy: | ±0.01 pH |
| pH Calibration: | 1 to 5 Point Calibration |
| ORP | |
| ORP Range: | ±2499 mV |
| ORP Resolution: | 0.1 mV |
| ORP Accuracy: | ±0.1 mV |
| ORP Calibration: | 2 Point (84.0 mV and 263 mV) |
| mV | |
| mV Range: | ±2499 mV |
| mV Resolution: | 0.1 mV |
| mV Accuracy: | ±0.1 mV |
| Temperature | |
| Temperature Range: | 0°C to 100°C |
| Temperature Resolution: | 0.01°C |
| Temperature Accuracy: | ±0.5°C |
| Resistivity | |
| Resistivity Range: | 5Ωcm to 50MΩcm |
| Resistivity Resolution: | 1 LSD (0.001) |
| Resistivity Accuracy: | ±2% FS |
| Resistivity Unit: | Ωcm |
| Salinity | |
| Salinity Range | 0 ppt to 120 ppt |
| Salinity Resolution | 1 ppt |
| Salinity Accuracy | ±2% FS |
| Salinity Unit | ppt (Parts Per Thousand) |
| TDS | |
| TDS Conversion Factor | TDS is derived from conductivity |
| TDS Range | 10 ppb to 200 ppt (10 ppb to 200000 ppm) |
| TDS Resolution | 1 ppb for lower range and 1 ppm for higher range |
| TDS Accuracy | ±2% FS |
| TDS Unit | ppt, ppm, ppb |
| Conductivity | |
| Conductivity Resolution | 1 LSD |
| Conductivity Accuracy | ±2% FS |
| Conductivity Unit | µS, mS |
| Conductivity Calibration | 5 Point Calibration |
| Auto Temperature Compensation | Upto 55°C |
| Auto Ranging | The smart software automatically selects the range, from 0.02mS to 2000mS/cm (with appropriate conductivity cell) |
| Conductivity Cells | Standard supply for cell constant 0.1 (cell with cell constant 1.0 can be ordered if required) |
| Conductivity Range | 0.02µScm⁻¹ to 2000mScm⁻¹ |
| Cell constant K=0.1 (0.02µS to 2mS) | |
| Cell constant K=1.0 (2mS to 200mS) | |
| Cell constant K=10 (200mS to 2000mS) | |
| Power Supply | 24V DC Mains Adaptor |
| Dimensions (L x W x H) | 230 mm x 190 mm x 80 mm |
| Weight | 1 Kg (approx) |
Ordering Information
Video